ACI 350-06 CODE PDF

ACI Code Requirements for Environmental Engineering Concrete Structures and Commentary, An ACI Standard [ACI Committee] on Read ACI Code Requirements for Environmental Engineering Concrete Structures by American Concrete Institute (ACI) for free with a 30 day free trial. ACI deletes ADM from the Code, but allows ACI continues to redraft and reballot a Code ACI Concrete Protection for

Author: Maladal Goran
Country: Comoros
Language: English (Spanish)
Genre: Music
Published (Last): 6 July 2006
Pages: 419
PDF File Size: 13.52 Mb
ePub File Size: 17.41 Mb
ISBN: 648-4-40546-934-8
Downloads: 33384
Price: Free* [*Free Regsitration Required]
Uploader: Meztitaxe

Wi moves with the tank walls as they respond to the ground shaking the fluid is assumed to be incompressible ack the fluid displace- ments small. Remember me on this computer. Reza Kianoush Javeed A. Among the subjects covered are: Sachdev Chair Jon B. Committee activities include the development of building codes and specifications; analysis of research and development results; presentation of construction and repair techniques; and education.

International Concrete Abstracts Portal

Calculate the equivalent weight of the tank wall shell Ww, roof Wr, and the stored liquid WL. Because ACI is written as a legal document, it may be adopted by reference in a general building code or in regulations governing the design and construction of environmental engineering concrete structures. Accordingly, the basic scope, format, and whose seismic design is not adequately covered by the mandatory language of Chapter 21 of ACI were retained leading national codes and standards.

Using the seismic zone determined in Step 1, find the zone factor Z from Table I; 3. Superimposed on these lateral unbalanced forces shall be the lateral hydrodynamic force resulting from the hydrodynamic pressure due to the effect of vertical acceleration pvy acting on each wall.

ACI Seismic Design of Liquid-Containing | Roy Quesada –

Explanations of the impulsive and convective pressures Pi and Pc are contained in Section R9. By joining you are opting in to receive e-mail. It’s easy to join and it’s free. But there’s not a whole lot else available. Register now while it’s still free!

  ELSO BEHINDERTEN WC SET PDF

It is the responsibility of the user of this document to establish health and safety practices appropriate to the specific circumstances involved with its use.

When using preformed slots, vertical bending moments induced in the wall by shear should be considered. Calculate the effective weight of the impulsive component of the stored liquid Wi, and the convective component Wc using Fig.

The code is concerned with freeze-thaw action on any exposed walls affecting the temperature steel for crack control. Join your peers on the Internet’s codw technical engineering professional community.

They are subject to uniquely different loadings, more severe exposure conditions, and more restrictive serviceability requirements than non-environmental building structures.

Engineering judgment may require a factor I greater than tabulated in Table 4. The sloshing increases and decreases the fluid pressure on the wall. This standard includes an effective mass coefficient, used in this standard, which represent some of the key applicable to the mass of the walls.

350M-06 Code Requirements for Environmental Engineering Concrete Structures & Commentary (Metric)

This code presents new material as well as modified portions of the ACI Building Code that are applicable to environmental engineering concrete structures. Criteria for liquid-tightness testing may be found in The table mentioned above does raise the question for walls with vertical control joints as to what the most economical spacing of the control joints would be considering the variation in the requirements of structural steel. For a tank with a height-to-diameter ratio of 1: Promoting, selling, recruiting, coursework and thesis posting is forbidden.

  ALESIS MIDIVERB III MANUAL PDF

This material may not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ACI.

The designer should also consider the effects of seismic forces on components outside the scope of this standard, such as piping, equipment for example, clarifier mechanismsand connecting walkways where vertical or horizontal movements between adjoining structures or surrounding backfill could adversely influence the ability of the structure to function properly National Science Foundation Except in farm areas where fertilizers are used, this should not pose a problem, but the maximum water-cement ration would still be 0.

In anchored, flexible-base, circular tanks Type 2. The minimum vertical steel is listed at. Red Flag This Post Please let us know here why this post is inappropriate. It could also be argued that for walls that are exposed in this locale, considering the limited 24 hour detention time available of the water in the tank to saturate the concrete walls, and considering the fact that most of the major storms in this area that would highly charge the tanks do not coincide with the time of extended freezing conditions, the freezing of the wall in a saturated state is highly unlikely.

Normally for buried tanks, this should not be a factor due to the insulating factor and heat sink effect of the surrounding soil matrix. Welding of reinforcement is covered by reference to the appropriate AWS standard. Serviceability requirements include liquid-tightness or gas-tightness.